PdM Solutions Program Design & Options
How to design a PdM Solutions program
- Select machines to monitor:
Choosing machines to survey is based on criticality - how does
a failure impact production and what are the costs to replace/repair.
VibrAlign engineers work closely with our clients to apply condition
monitoring to the right rotating assets to ensure maximum value.
- Select frequency of monitoring:
How often we collect data for analysis not only involves criticality,
but also the nature of the process, hours of operation, and the
costs of monitoring. Again, we work closely with each client
to decide the appropriate level of service that will deliver
performance and value. Typically, machines are surveyed every
4, 8 or 12 weeks.
- Accessibility:
Some machines that are desirable to monitor are not accessible
for portable sensor mounting. In this case, we can provide hardware
to permanently mount sensors wired to a junction box for data
acquisition. Installation is performed by a certified VibrAlign
analyst.
PdM Solutions Program Options
- Program Term. One and two year programs are available.
- Data Collectors. Facilities have
the option to either purchase their data collectors or rent them
for the term of the PdM Solutions program. The rental fee or purchase
price will be included in the PdM Solutions monthly fee. We offer
a range of data collectors:
a. DCA50—this is typically the instrument
delivered with a PdM Solutions program. State of the art 4 channel
data collector with intuitive “Windows Explorer” interface
and possibility for balance upgrade.
b. DCA31—Should you choose to opt
out on owning the data collector, VibrAlign will ship a DCA 31
loaner for each scheduled survey. A return shipping label is included
for expedited return to VibrAlign. This option is less expensive
for programs with very few machines and less frequent surveys.
c. DCX—Full-featured data collector
combined with ExpertALERT software onboard. The DCX is a rugged
tablet PC with similar data collection functionality to the DCA50,
but with full data analysis software included. Consider this option
if the near term goal is to train an in-house analyst who will
completely take over the program within 2 years.
Several options are available as add-ons to your PdM Solutions program including:
- Balancing: Additional hardware
is required for your data collector, as well as 1.5 additional
days training in field balancing.
- Alignment: Choose one of VibrAlign’s
laser alignment systems to include in your PdM Solutions program.
1–2 days additional hands-on training will be delivered during
your installation visit.
- Certification: VibrAlign is authorized by the Vibration Institute
to conduct Category I and II certification classes. Testing is
administered at the conclusion of coursework.
|