By on April 27, 2017

A VibrAlign customer recently called, stating they were having repeatability problems with aligning a small motor to gearbox to pump.  After some phone conversation, I asked if they could send me photos of the machine, and the discrepancy in the measurements.  After seeing them, I knew what the problem was.

 

Machines with small diameter shafts can present a unique challenge.  The coupling used is generally flexible, but not when it’s mounted on small diameter shafts. If misalignment is present, the coupling can cause the shafts to deflect, or bend.  This means that the lasers (or dials) do not read true rotation centerlines.  The effect is that you measure, shim and move as directed, and the alignment result is not as expected.

Here’s how we determined the problem.  The first measurement is with the coupling insert in place.

The coupling insert was then removed by sliding the hubs back far enough to remove it.  No changes were made to the positions of either the gearbox or pump.

 

The second image was taken with the insert removed.  While the change is not large, it is enough to make the aligner doubt the tool.

The alignment was done with the insert out, and was completed quickly, with values that made sense.

If you encounter a similar situation, taking the insert out means you are truly aligning shaft centerlines.

Save Time. Save Money. Save the Machine.

 

About the Author

Stan Riddle joined VibrAlign in 2008. He has over 35 years experience in aligning industrial machinery. Stan received his AAS Degree in Machinist Technology from Surry Community College in Dobson, NC, and also holds a diploma in Industrial Systems Technology from Forsyth Technical Community College in Winston-Salem, NC, where he was also an instructor in the program.

Stan began his maintenance career working as a machinist and millwright for companies such as Weyerhaeuser, R.J. Reynolds, and Tyco Electronics. He also has over 25 years experience in Predictive Technologies, such as vibration analysis, thermography, oil analysis, and ultrasonic inspection. He is a certified Level III Vibration Analyst with the Vibration Institute, and is a Past Chairman and Board Member of the Piedmont Chapter.