Acoem AT-400 Nominated for Plant Engineering's 2024 Product of the Year! Vote Now to Help Us Win

Got Alignment Questions? We Are Here To Help!

VibrAlign’s Team of 6 dedicated Technical Trainers conducted over 200 “Shaft Alignment Best Practices” Classes across America in 2015.

Our classes were conducted in all types of industry including but not limited to:

  • Food and Beverage
  • Power Generation (fossil fuel, nuclear, & wind)
  • Gas Compression
  • Petro-Chemical
  • Mining
  • Water/Waste Water
  • HVAC (facilities maintenance)
  • Construction/Contracting
  • Various Types of Manufacturing.

We have performed precision shaft alignments on rotating machinery ranging in size from 5 HP to Thousands of HP. So, if you have an alignment question regarding a particular application chances are we have aligned it.

The Technical Training Team can be reached by calling our main office in Richmond, VA at 800.394.3279 or go to our website for a list of the trainers. http://acoem.us/contact/field/ . If you have questions regarding a training class contact Rick Coad our Training Coordinator @ 800.394.3279, Ext. 119.

So whether you are using dial indicators or a laser alignment system, work in an underground mine, a wind turbine 300 ft. above ground or any place in between please give us call, we are here to help you.

No alignment question is too small to ask and telephone support is always free! So give us a call!

photo-staff

Share Blog Post

5 Comments

  1. […] industry including but not limited to: Food and Beverage Power Generation (fossil fuel, […] Read More Source: The Alignment […]



  2. Tsholo Seatle on February 20, 2016 at 1:20 pm

    Hi Team

    I just want to find out where to mount the V-block on the coupling or shaft because am off the opinion when alignment is conducted we align the shaft. There reason am asking this question it because some machine the is no sufficient space between the coupling and shaft. What is the best way to set up the Sensor Display.

    Regards

    Tsholo Seatle



  3. Brad Case on February 22, 2016 at 4:01 pm

    Tsholo, you are correct, we are aligning the shaft’s rotational centerlines. On machines that you described it is acceptable to mount the sensor brackets on the coupling hub(s) as long as the hub is secured to the shaft (shrink fit, etc). As both sensor brackets are mounted to a fixed point and the shafts are rotated when taking alignment readings the sensors (or dial indicators) “SEE” the rotational centerlines.

    Thanks for your question.



  4. Sabuhi Alakbarov on November 17, 2018 at 12:45 pm

    Hello Team,

    Could you please tell me, why laser is generally mounted on pump side (stationary machine), and sensor on motor side (movable machine)? Is there any difference?

    Thanks in advance

    Best regards,
    Sabuhi Alakbarov



  5. Brad Case on November 19, 2018 at 12:00 pm

    Sabuhi, The laser alignment system you are referring to is not a Fixturlaser Shaft Alignment System. All Fixturlaser Shaft Alignment Systems utilize a S (Stationary) Sensor and M (Movable) Sensor. Each sensor emits a laser beam and has a digital detector (receives the laser beam from the opposing sensor). As there are two lasers and detectors we are able to use the Verti-Zontal Process to align most machines in 1 or 2 moves.

    Thanks for your comment.



Subscribe to the
Acoem USA Blog

  • This field is for validation purposes and should be left unchanged.