Posts tagged with: Fixturlaser Smart Machine Checker

Balancing How To #5 – How A Correction Weight and Location is Calculated

| | | |

By on October 9, 2019

In our last “How To” we talked about the trial run – using a trial weight and location, to calculate the amount and location of a correction weight, which should correct the unbalance.  Most modern-day balancing tools do the math for you.  Even though these tools calculate the correction weight and location, it is good […]

Read More

Calculating VFD Motor Speed

| | | |

By on March 13, 2018

When using the Fixturlaser Smart Machine Checker (SMC) or any of VibrAlign’s Condition Monitoring Tools, there are typically only two variables you need to know for an accurate diagnosis of your machine.  You need the horsepower of the motor and the correct rotating speed.  This information will usually be stamped on the motor data plate.  […]

Read More

X, Y, Z Axis. What do they stand for?

| | | | | |

By on February 1, 2018

Everything must have perspective, a point of view, to be communicated. To communicate the three spatial dimensions, we use the X,Y, Z coordinates. These denote height, width and depth. In referring to machinery we use the same X,Y, Z denotations, but we give them different values or meanings. To make it even more interesting, there […]

Read More

The New Age of Machinery Diagnostics

| | | |

By on January 16, 2018

With the introduction of the OneProd Hawk in April of 2015, VibrAlign shed light on the idea that the future of Machinery Diagnostics was about to get easier; That you can achieve a second level diagnosis on any machine without help from a professional vibration analyst. It just took a tool that empowers mechanics to […]

Read More